Component Sorting Process for Home Appliances
Component Sorting Process for Home Appliances
Problem:
Micro-stoppages occurred 5 times a day due to parts getting stuck in the sorting plate.
Each micro-stoppage required 8 minutes to recover.
This caused 40 minutes of downtime each day.
The air cylinder’s speed was affected by surrounding equipment, slowing down the process.
Micro-stoppages occurred 5 times a day due to parts getting stuck in the sorting plate.
Each micro-stoppage required 8 minutes to recover.
This caused 40 minutes of downtime each day.
The air cylinder’s speed was affected by surrounding equipment, slowing down the process.
Cause of the Issue:
The sorting plate couldn’t move fast enough, leading to parts getting stuck.
The air cylinder was influenced by surrounding air equipment, causing a decrease in speed.
Solution:
Adopted the EleCylinder EC-RR6 for smoother and more precise movements.
Unlike air cylinders, the electric cylinder is not affected by the surrounding environment, ensuring consistent speed and performance.
Results:
Micro-stoppages were eliminated entirely.
Adjustment time was reduced by 40 minutes per day.
Production efficiency improved significantly.
EC-RR6