<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Intelligent Actuator &#124; Electric Actuators &#187; FAQs</title>
	<atom:link href="http://www.intelligentactuator.com/category/faqs/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.intelligentactuator.com</link>
	<description>Electric actuators, Linear actuator, Single-axis actuators, Rotary actuator, Cartesian, SCARA, Table-top robot, Linear servo actuator, positioners / controllers, and motion control software.</description>
	<lastBuildDate>Fri, 03 Feb 2012 23:37:33 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>ISO 9001: 2000 / JIS Q9001: 2000 Certified</title>
		<link>http://www.intelligentactuator.com/iso-9001-2000-jis-q9001-2000-certified/</link>
		<comments>http://www.intelligentactuator.com/iso-9001-2000-jis-q9001-2000-certified/#comments</comments>
		<pubDate>Mon, 08 Feb 2010 03:50:43 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[FAQs]]></category>
		<category><![CDATA[ISO Certification]]></category>

		<guid isPermaLink="false">http://www.intelligentactuator.com/?p=1873</guid>
		<description><![CDATA[Through our uncompromising pursuit for &#8220;Quality,&#8221; IAI has instituted ISO 9001:2000 and JIS Q9001:2000, which is a quality management system maintained by the International Organization for Standardization and Japanese Industrial Standards. IAI has been certified for ISO 9001:2000 and JIS Q9001:2000 by an independent auditor to be in conformance with ISO 9001:2000 and JIS Q9001:2000. [...]]]></description>
		<wfw:commentRss>http://www.intelligentactuator.com/iso-9001-2000-jis-q9001-2000-certified/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>RoHs, CE Mark, UL Listed Compliance Table</title>
		<link>http://www.intelligentactuator.com/rohs-ce-mark-ul-listed-compliance-table/</link>
		<comments>http://www.intelligentactuator.com/rohs-ce-mark-ul-listed-compliance-table/#comments</comments>
		<pubDate>Sun, 07 Feb 2010 04:46:23 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[FAQs]]></category>

		<guid isPermaLink="false">http://www.intelligentactuator.com/?p=1170</guid>
		<description><![CDATA[[5/29/2009 Update] Compliance √ : Standard • : Option Δ : Special Order N/A : Not Available 1.ROBO Cylinder® Product Configuration Series Name Type &#8211; Model RoHS Compatible CE Mark Compatible UL Listing Compatible ROBO Cylinder® ERC2 Slider SA6 / SA7 √ √ - Rod RA6 / RA7 √ √ - RCL Rod RA1L / [...]]]></description>
		<wfw:commentRss>http://www.intelligentactuator.com/rohs-ce-mark-ul-listed-compliance-table/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Robo Cylinder Controller FAQ</title>
		<link>http://www.intelligentactuator.com/robo-cylinder-controller-faq/</link>
		<comments>http://www.intelligentactuator.com/robo-cylinder-controller-faq/#comments</comments>
		<pubDate>Mon, 02 Feb 2009 00:01:44 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[FAQs]]></category>

		<guid isPermaLink="false">http://www.intelligentactuator.com/?p=1293</guid>
		<description><![CDATA[Q: We powered up the Robo Cylinder, but we can&#8217;t run it with either the software, teach pendant or through the I/O. On the software and teach pendant, we get a &#8217;20D error&#8217;. A: In order to run the Robo Cylinder, the &#8216;Sudden Stop&#8217; input must be on. It&#8217;s a normally-closed input designed to stop [...]]]></description>
		<wfw:commentRss>http://www.intelligentactuator.com/robo-cylinder-controller-faq/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>SEL-A / B Controller FAQ</title>
		<link>http://www.intelligentactuator.com/sel-a-b-controller-faq/</link>
		<comments>http://www.intelligentactuator.com/sel-a-b-controller-faq/#comments</comments>
		<pubDate>Thu, 22 Jan 2009 22:34:08 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[FAQs]]></category>

		<guid isPermaLink="false">http://www.intelligentactuator.com/?p=1467</guid>
		<description><![CDATA[Q: Currently we&#8217;re running a 4-axis system (X, Y, Z, and Rotary) and would like to add a 60W fifth axis for part indexing. We&#8217;ve got a SuperSEL A controller. Is this field-upgradeable to five axes? A: No. The SuperSEL A only handles up to 4 axes of control. The next controller up is a [...]]]></description>
		<wfw:commentRss>http://www.intelligentactuator.com/sel-a-b-controller-faq/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>SEL-E / G Controller FAQ</title>
		<link>http://www.intelligentactuator.com/sel-e-g-controller-faq/</link>
		<comments>http://www.intelligentactuator.com/sel-e-g-controller-faq/#comments</comments>
		<pubDate>Thu, 22 Jan 2009 18:24:07 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[FAQs]]></category>

		<guid isPermaLink="false">http://www.intelligentactuator.com/?p=1530</guid>
		<description><![CDATA[Q: The actuators have been connected, the I/O powered up, the brake connected and creep sensor plugged in, When we try to home the system, we come up with an &#8216;A4&#8242; error on the controller. A: Check to see that the slide is not past the creep sensor in the direction of the homing hard [...]]]></description>
		<wfw:commentRss>http://www.intelligentactuator.com/sel-e-g-controller-faq/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>IH SCARA Actuator FAQ</title>
		<link>http://www.intelligentactuator.com/ih-scara-actuator-faq/</link>
		<comments>http://www.intelligentactuator.com/ih-scara-actuator-faq/#comments</comments>
		<pubDate>Tue, 20 Jan 2009 23:38:37 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[FAQs]]></category>
		<category><![CDATA[Obsolete Products]]></category>

		<guid isPermaLink="false">http://www.intelligentactuator.com/?p=1682</guid>
		<description><![CDATA[The IH SCARA has been moved to the obsolete archive. Q: We powered down our backup IH-SCARA robot for about 6 months. When we powered back up, the IH-SCARA&#8217;s encoder feedback was extremely wrong. A: There is a lithium battery backup of the IH-SCARA&#8217;s absolute encoders. This battery only goes into effect when the unit [...]]]></description>
		<wfw:commentRss>http://www.intelligentactuator.com/ih-scara-actuator-faq/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>IH SCARA Controller FAQ</title>
		<link>http://www.intelligentactuator.com/ih-scara-controller-faq/</link>
		<comments>http://www.intelligentactuator.com/ih-scara-controller-faq/#comments</comments>
		<pubDate>Tue, 20 Jan 2009 21:57:58 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[FAQs]]></category>
		<category><![CDATA[Obsolete Products]]></category>

		<guid isPermaLink="false">http://www.intelligentactuator.com/?p=1606</guid>
		<description><![CDATA[The IH SCARA has been moved to the obsolete archive. Q: In the Controller Operating Manual, I noticed that there is an emergency stop contact input listed on pin 2 of the I/O diagram. I tried to use this, but it doesn&#8217;t seem to be working. A: That is actually a typographical error. There is [...]]]></description>
		<wfw:commentRss>http://www.intelligentactuator.com/ih-scara-controller-faq/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>MSEL Controller FAQ</title>
		<link>http://www.intelligentactuator.com/msel-controller-faq/</link>
		<comments>http://www.intelligentactuator.com/msel-controller-faq/#comments</comments>
		<pubDate>Tue, 20 Jan 2009 18:42:19 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[FAQs]]></category>

		<guid isPermaLink="false">http://www.intelligentactuator.com/?p=1637</guid>
		<description><![CDATA[Q: I&#8217;ve got the SelWin v4.xx software, can I program the MSEL with this? A: No. The MSEL has its own dedicated software. It&#8217;s MS DOS-based and the final release version of this software was v2.08, released in 11/93. Q: I&#8217;ve used some of your other controllers and all had a limit switch connector on [...]]]></description>
		<wfw:commentRss>http://www.intelligentactuator.com/msel-controller-faq/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>ISP / ISPD, IS / ISD Actuator FAQ</title>
		<link>http://www.intelligentactuator.com/isp-ispd-is-isd-actuator-faq/</link>
		<comments>http://www.intelligentactuator.com/isp-ispd-is-isd-actuator-faq/#comments</comments>
		<pubDate>Mon, 03 Feb 2003 19:04:20 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[FAQs]]></category>

		<guid isPermaLink="false">http://www.intelligentactuator.com/?p=1540</guid>
		<description><![CDATA[Q: How is it the IS/ISD/ISD-CR is so short overall? Isn&#8217;t the motor coupled to the ballscrew, and if so, when should I replace the coupler/brushes/motor? A: The &#8220;IS&#8221; in IS/ISD/ISD-CR stands for &#8220;Integrated Series&#8221; meaning that the ballscrew and motor are integrated. There is no coupling for the motor because the motor windings fit [...]]]></description>
		<wfw:commentRss>http://www.intelligentactuator.com/isp-ispd-is-isd-actuator-faq/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>